12.7¢Oncor middle 12-month price at 2,000 kWh
12.7¢CenterPoint middle 12-month price at 2,000 kWh
Short answer

Cooling kWh equals tons times 12,000, divided by SEER2, divided by 1,000, then times hours and days. At the Oncor middle twelve-month price, each kWh is 12.7¢. A kilowatt-hour (kWh) is the energy on the bill. The tool does that math. Compare plans by ZIP for the rest of the house.

What do you need right now?
Compare plans at my ZIP

Partner tool A partner runs the plan finder. If you sign up, it may pay us a fee. We do not take payment to change a score, a rank, the order of our rankings, or what we write about a company. Paid links and partner tools are always labeled as paid.

12.7¢Oncor middle 12-month price at 2,000 kWh
12.7¢CenterPoint middle 12-month price at 2,000 kWh
15.2ENERGY STAR SEER2 on the hot-humid table, where the box starts
8 hoursOur example runtime, not a reading from your house

The 5 things to know

  • This is an estimate for one unit. The house, the insulation, and the weather change real use.
  • One ton means 12,000 BTU per hour in this calculator. BTU means British thermal unit. SEER2 is the cooling score, in BTU per watt-hour.
  • Eight hours a day is our example. The Department of Energy note we opened does not give a Texas summer day.
  • The cents already include delivery. The Electricity Facts Label (EFL) is the all-in price. Do not add the wires charge on top.
  • Compare plans by ZIP when you want offers for the whole house, not only this unit.

Built on public data from the Department of Energy guide for an efficient central air conditioner, its test-procedure notice, the Energy Information Administration notes on the British thermal unit and the kilowatthour, and the Texas rule that sets the Electricity Facts Label.

01 · Try it

Run a summer month

The size box runs from 1.5 to 5 tons and starts at 3 tons. That 3 is a starter, not a claim about your house. SEER2 starts at 15.2. On the Department of Energy hot-humid table, which includes Texas, 15.2 is the ENERGY STAR score, 13.4 is the less-efficient score, and 23.5 is the best available score listed as of December 2024. This box accepts 13.4 through 22, so a 23.5 unit is above the box.

Hours start at 8. That 8 is our example. Days start at 30. The price is the middle or the lowest twelve-month plan at 2,000 kWh in your wires area, or cents you type from a bill.

What does the air conditioner add this month?Free. What you type stays in this browser.

The wires company on your bill. The plan seller is a different company.

One ton is 12,000 BTU per hour. 3 tons is a starter for the box, not a size for your house.

Starts at 15.2, the ENERGY STAR score on the Department of Energy hot-humid table. The box accepts 13.4 to 22.

8 hours is our example, not a reading from your house.

Starts at 30 days. Type the days you want to count.

Used only for the bill choice. Leave it blank for a plan-list price.

Pick the area and press the button. You get the air conditioner kWh, the dollars for the month, and what one step up in SEER2 changes in this math.

This is a summer estimate for one air conditioner. The house, the insulation, and the weather can move the real kWh. Eight hours a day is our example. A one-degree thermostat change is not included. The page does not keep what you type.

SizeOne ton in this formula is 12,000 BTU per hour.
ScoreA higher SEER2 uses fewer kWh for the same tons.
PriceThe tool multiplies the 2,000 kWh label price.

The tool prices one unit. Compare plans by ZIP for the full house.

02 · Tons and SEER2

How the formula works

The line on this page is kWh = tons x 12,000 / SEER2 / 1,000 x hours x days.

One ton, in this calculator, is 12,000 BTU per hour. EIA says a British thermal unit is the heat required to raise 1 pound of water by 1 degree Fahrenheit. The Department of Energy states SEER2 in British thermal units per watt-hour. Dividing BTU per hour by SEER2 gives watts. Dividing by 1,000 turns watts into kilowatts. Hours and days then make kWh.

The Department's 2016 test-procedure notice uses "per 12,000 Btu/h certified cooling capacity" as a capacity step. It does not, in the lines we read, say the word ton. We still use 12,000 BTU per hour as one ton because that is the step the formula needs.

What each piece of the formula means
PiecePlain meaning
TonsCooling size. One ton here is 12,000 BTU per hour.
SEER2Cooling score. A higher score uses fewer kWh for the same tons in this math.
Hours and daysHow long it runs. Eight hours is our example.
kWhTons times 12,000, divided by SEER2, divided by 1,000, times hours, times days.

On January 1, 2023, the Department of Energy changed the test and the names. The older cooling score was SEER. The score now is SEER2. Texas is in the hot-humid, Southeast group on that table, with Alabama, Florida, Louisiana, and the other states the footnote lists.

For a 36,000 Btu per hour unit, the hot-humid note says the unit is "operating 3,409 per year." The sentence does not say hours. Other climate notes on the same page do say hours. We do not turn 3,409 into a daily default.

Hot-humid table, yearly kWh for a 36,000 Btu per hour unit
Less efficient, SEER2 13.4
9,159 kWh a year
ENERGY STAR, SEER2 15.2
8,074 kWh a year
Best available, SEER2 23.5
5,222 kWh a year

Department of Energy hot-humid table. Not your house, and not this tool's month. The highlighted row is where the SEER2 box starts.

One step up in SEER2 divides by a larger number, so the kWh fall. The tool shows that gap in dollars at the price you picked. A one-degree warmer setting is left out. We did not open a Department of Energy page that states a percent for one degree, so we do not print one. A lower cents price changes this math. Compare plans by ZIP to see live offers.

03 · Area prices

What moves a summer bill

The same unit costs more where the 2,000 kWh price is higher. Summer is when that price matters most, because the air conditioner adds a large pile of kWh on top of the rest of the house. A high electric bill in July often has cooling in it, plus the plan price, plus a rate that looked low only at a smaller usage.

Middle and lowest 12-month prices at 2,000 kWh
AreaMiddle priceLowest price
Oncor12.7¢11.8¢
CenterPoint12.7¢11.5¢
AEP Texas Central11.5¢10.7¢
AEP Texas North12.1¢10.9¢
TNMP14.2¢11.2¢

Those cents are label prices. The EFL must show the total average price at 500, 1,000, and 2,000 kWh. Delivery is inside that average, not a second line you add in this tool. Houston homes on CenterPoint can read Houston electricity rates next to the CenterPoint row. The state home average, 15.91¢, is not one of these plan prices. Summer use is high, so compare plans by ZIP at the 2,000 kWh level.

04 · Plan, then habits

Pay less for cooling

Shop the planHigh use

The 2,000 kWh price is on the most kWh in summer.

Then the unitSEER2

One step up is math the tool can show. Your house can differ.

Plan choice comes first. A lower price at 2,000 kWh trims every summer kWh, not only the air conditioner. See which sellers have the low prices on the best electricity providers page, and match the price to your usage on compare electricity rates.

  • Shop the 2,000 kWh price before you shop a new unit. The hot months are when that price is on the most kWh.
  • A higher SEER2 uses fewer kWh in the formula above. The tool's one-step line is that math, not a promise for your house.
  • Raise the setpoint when you can stand it, and keep doors and filters in good shape. We do not attach a percent to one degree.
  • A mini split can use the same formula if you know its tons and its SEER2. We do not have a separate mini-split watt figure.
  • The yearly bars above are a federal test for one size. They are not a Texas month.
  • Replacing the unit is a different decision from running it. See the pages in the next section.

Plan choice comes first. Compare plans by ZIP, then keep the runtime habits you can live with.

05 · New equipment

Bigger equipment choices

Running cost is one month of kWh. Buying a unit, or switching to a heat pump, is a larger choice with its own prices. Our heat pump versus AC page is that comparison. Our AC replacement cost page is about the purchase, not this monthly math.

Utility rebates for equipment and for air sealing sit on the utility energy rebates page. Read the rules on that page before you count a rebate in a budget. The Electricity Facts Label still decides the cents you multiply. After you know the run cost, compare plans by ZIP for the plan itself.

Your next step

Run the summer estimate, then compare twelve-month plans by ZIP at heavy use. A lower price at high monthly use matters most while the air conditioner is on.

Compare plans at my ZIP

Partner tool A partner runs the plan finder. If you sign up, it may pay us a fee. We do not take payment to change a score, a rank, the order of our rankings, or what we write about a company. Paid links and partner tools are always labeled as paid.

Read nextHeat pump or central AC, when the monthly run cost is not the only question Read it
06 · Quick answers

Questions, answered

How much does it cost to run an air conditioner per month in Texas?

Use tons times 12,000, divided by the SEER2 score, divided by 1,000, times hours, times days. Multiply those kWh by the 2,000 kWh plan price for your wires area, or by the cents on your bill. The tool does that. Real use still depends on the house and the weather.

What is an AC electricity cost calculator?

It turns size, efficiency, and hours into kWh and dollars for one air conditioner. Ours uses SEER2 and a Texas plan price at 2,000 kWh. It is an estimate for one unit, not a whole-home bill.

How do I figure air conditioner electricity cost from SEER2?

SEER2 is BTU per watt-hour. One ton in this formula is 12,000 BTU per hour. Divide tons times 12,000 by the SEER2 score, divide by 1,000, then multiply by hours and days. That product is kWh.

Why is my summer electric bill high in Texas?

Cooling adds a lot of kWh, and a price that looked low at small usage can be higher at 2,000 kWh. The plan price and the hours both move the month. Our high-bill page lists other causes besides the air conditioner.

How much electricity does a mini split use?

This page does not have a separate mini-split watt number. If you know the mini split's tons and its SEER2, the same formula applies. If you do not know those two, the tool cannot guess them.

Does a higher SEER2 cut the kWh?

In this formula, yes. kWh falls when SEER2 rises, because the score is in the bottom of the fraction. The tool shows one step up. Your house can still use a different amount.

What did the 2023 SEER change do?

On January 1, 2023, the Department of Energy changed the test. The cooling score's name became SEER2. Texas is in the hot-humid group on the Department's table.

Does one degree warmer on the thermostat have a set percent?

Not on this page. We did not cite a Department of Energy percent for one degree, so the tool leaves that out. You can still type fewer hours if you know you will run the unit less.

Are delivery charges added on top of the cents?

No. The EFL average price already reflects recurring charges, and a variable product's label includes wires charges that may be passed through. The tool multiplies only the all-in cents.

Is 8 hours a Texas rule?

No. Eight hours is our example so the box is not empty. Type the hours you expect. The Department's hot-humid note gives 3,409 per year for a 36,000 Btu per hour unit, and that sentence does not say hours in a day.

Where to next

What do you want to do next?

Browse every Texas guide by topic below, or start at our Texas hub.

Every Texas guide, by topic

Sources

Sources and updates

Sources (5)
  • U.S. Department of Energy, Federal Energy Management Program, Purchasing energy-efficient residential central air conditioners: Effective Jan. 1, 2023, DOE changed the test and the names from SEER to SEER2. SEER2 is shown in Btu/Wh. Hot-humid table, which includes Texas: SEER2 23.5, 15.2, and 13.4, with annual energy use 5,222 kWh, 8,074 kWh, and 9,159 kWh for a 36,000 Btu/h unit. The hot-humid note says that unit is operating 3,409 per year. Best available is the highest ENERGY STAR model as of December 2024. Read November 9, 2026.
  • U.S. Department of Energy, Energy Conservation Program: Test Procedures for Central Air Conditioners and Heat Pumps, supplemental notice: Uses "per 12,000 Btu/h certified cooling capacity" as a capacity step. The lines we read do not define the word ton. Read November 9, 2026.
  • U.S. Energy Information Administration, Glossary: British thermal unit: A British thermal unit is the heat required to raise the temperature of 1 pound of liquid water by 1 degree Fahrenheit. Read November 9, 2026.
  • U.S. Energy Information Administration, Glossary: kilowatthour: A kilowatthour is 1 kilowatt of power expended for 1 hour. Read November 9, 2026.
  • Public Utility Commission of Texas, §25.475, General Retail Electric Provider Requirements and Information Disclosures: The EFL shows total average price in cents per kWh at 500, 1,000, and 2,000 kWh. The average reflects recurring charges. A variable product includes any TDU charges that may be passed through. Header effective date 01/06/2022. Read November 9, 2026.
Changelog · 1 update, newest November 9, 2026
  • November 9, 2026: Page published.

How to cite this page: The Day Company, "What it costs to run an air conditioner in a Texas summer", updated November 9, 2026, https://theday.company/tx/ac-electricity-cost.

Reviewed is the last day a person re-checked every number on this page.

The Day Company is not a wires company, a plan seller, or the Public Utility Commission of Texas. The formula uses one ton as 12,000 BTU per hour. Eight hours a day is our example. The yearly kWh bars are the Department of Energy table, not your meter. The tool is an estimate, not a bill and not legal advice. A wrong fact can be sent to info@theday.company.